Sign In | Join Free | My burrillandco.com
Home > Online Gas Monitoring System >

‌Grid-based Air Quality Monitoring Micro Station‌ PM2.5 SO2 CO NO2 O3 TVOC Online Gas Monitoring System

Nanjing Juge Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap ‌Grid-based Air Quality Monitoring Micro Station‌ PM2.5 SO2 CO NO2 O3 TVOC Online Gas Monitoring System from wholesalers
     
    Buy cheap ‌Grid-based Air Quality Monitoring Micro Station‌ PM2.5 SO2 CO NO2 O3 TVOC Online Gas Monitoring System from wholesalers
    • Buy cheap ‌Grid-based Air Quality Monitoring Micro Station‌ PM2.5 SO2 CO NO2 O3 TVOC Online Gas Monitoring System from wholesalers

    ‌Grid-based Air Quality Monitoring Micro Station‌ PM2.5 SO2 CO NO2 O3 TVOC Online Gas Monitoring System

    Ask Lasest Price
    Brand Name : JUGE
    Model Number : AG-600-A8
    Certification : IOS9001, CE
    Price : USD1000-10000
    Payment Terms : Online order,T/T
    Supply Ability : 100 Unit/Week
    Delivery Time : 5-8 working days
    • Product Details
    • Company Profile

    ‌Grid-based Air Quality Monitoring Micro Station‌ PM2.5 SO2 CO NO2 O3 TVOC Online Gas Monitoring System

    Grid-based Air Quality Monitoring Micro Station‌ PM2.5 SO2 CO NO2 O3 TVOC Online Gas Monitoring System


    >>Overview

    The Air Quality Online Monitoring System primarily consists of a particulate matter measurement device, gas monitoring modules, and a data acquisition and wireless transmission unit. Combined with monitoring platform software, it enables functions such as air quality publishing, comprehensive data analysis, pollution exceedance alarms, urban environment photography, and video surveillance.

    >>Feature

    High Integration:‌ Can simultaneously integrate sensors for particulate matter, SO₂, CO, NO₂, O₃, TVOC, and meteorological five-parameter sensors.

    Optical Sizing:‌ Utilizes optical particle sizing technology for simultaneous monitoring of PM₁.₀, PM₂.₅, PM₁₀, and TSP.

    Constant Flow Control:‌ Incorporates flow feedback for constant flow control, ensuring sampling volume stability and enhancing accuracy.

    Built-in Protection:‌ Features sheath gas protection and gas path protection functions.

    Professional Design:‌ Structural design by professional design institutes for easy installation.

    Tiered Air Paths:‌ Features dual-pump air paths with main channel for particulates and auxiliary channel for gas modules.

    Data Stability:‌ Equipped with temperature and humidity sensing, gas cross-interference algorithms, zero drift compensation, and calibration across measurement ranges.

    Dynamic Dehumidification:‌ Can be equipped with a dynamic heating dehumidification sampling system to avoid data distortion in humid environments.

    Data Transmission:‌ 4G, RS232/RS485.

    Data Export:‌ Features USB port and/or SD card slot, supporting local data export (includes local storage with capacity >530,000 records).

    Weather Resistance:‌ Protection against rain, snow, and lightning.

    Traceability:‌ Traceable to NIST (National Institute of Standards and Technology).

    Resume Transmission:‌ Features power failure protection and data resume/re-transmission upon network restoration.

    Information & QC:‌ Includes device information management, data management, and data quality control functions.

    Local Display:‌ Equipped with LCD display and local debugging functions.

    Multi-stage Filtration:‌ Incorporates a two-stage or higher filtration system to prevent foreign matter from affecting sensor accuracy and precision.

    Service Life:‌ Main unit >10 years; Particulate Matter Sensor >5 years; Gas Sensors >2 years.

    Calibration/Zeroing:‌ Supports automatic/manual zero calibration and calibration functions.


    >>Main technical parameters
    Particulate Matter (PM)
    Measurement MethodLaser Scattering
    Measured ParametersPM₂.₅, PM₁₀, PM₁₀₀, TSP
    Concentration Range0 - 30 mg/m³
    Concentration Precision0.1 µg/m³
    Concentration Accuracy±10%
    Inorganic Gases
    Measurement MethodElectrochemical Method
    Measured ParametersSO₂, NO₂, CO, O₃, TVOC
    Concentration RangeSO₂: 0-1 ppm
    NO₂: 0-1 ppm
    CO: 0-200 ppm
    O₃: 0-5 ppm
    TVOC: 0-20 ppm
    Concentration PrecisionSO₂: 0.001 ppm
    NO₂: 0.001 ppm
    CO: 0.01 ppm
    O₃: 0.001 ppm
    TVOC: 0.001 ppm
    Concentration AccuracySO₂: ±5%
    NO₂: ±5%
    CO: ±5%
    O₃: ±5%
    TVOC: ±5%
    Meteorological Parameters
    TemperatureRange: -50 ~ 100°C; Accuracy: ±0.3°C
    HumidityRange: 0 ~ 100% RH; Accuracy: ±3% RH
    Wind SpeedRange: 0~30 m/s; Accuracy: ±1 m/s (≤10 m/s), ±10% (>10 m/s)
    Wind DirectionRange: 0~360°; Accuracy: ±3°
    Atmospheric PressureRange: 1~120 kPa; Accuracy: ±0.15 kPa
    Data Transmission4G transmission; Capable of uploading to data platforms; Compliant with China's standard HJ212-2017 communication protocol.
    Ingress Protection (IP)IP53
    Power SupplyAC 220V
    Output InterfacesRS232, RS485, etc.
    Installation MethodPole-mounted/Bracket-mounted


    Quality ‌Grid-based Air Quality Monitoring Micro Station‌ PM2.5 SO2 CO NO2 O3 TVOC Online Gas Monitoring System for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Nanjing Juge Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)